Page 52 - RoboCilindri, rcp2/rcp3, robocilindri, sinta,
P. 52

Type MiniStandardControllers IntegratedRod TypeMiniStandardControllers IntegratedTable/Arm /Flat TypeMini StandardGripper/ Rotary TypeLinear Motor TypeCleanroom TypeSplash-ProofControllersPMEC /AMECPSEP /ASEPROBO NETERC2 PCON ACON SCON PSEL ASEL SSEL XSELPulse MotorServo Motor (24V)Servo Motor (230V)Linear MotorRCP2-BA7/BA7U RoboCylinder Belt Type 68mm Width Pulse Motor Top-Mounted Motor / Bottom-Mounted MotorRCP2 RoboCylinder Slider■ Configuration: RCP2Series Typeabsolute encoder models are labeled as "I".I: Incremental Top-mounted motor * The SimpleP1: P3:PCON RPCON PSEL PMEC PSEPBA7 : Belt type42 □ size* See page Pre-35 for explanation of each code that makes up the configuration name.BA7U: Belt type Bottom-mountedCustom Length Robot cablemotorIEncoder42P 54Motor Lead 42P: Pulse motor 54:54mmStroke 600: 600mm1200:1200mm (50mm pitch increments)Compatible ControllersCable LengthN : None P : 1mS : 3m M : 5m X □□ : R □□ :OptionNM: Reversed-home■ Speed vs. Load CapacityDue to the characteristics of the pulse motor, the RCP2 series' load capacity decreases at high speeds. In the table below, check if your desired speed and load capacity are supported.Load Capacity (kg)IONTPNotes on Selection(1) Operating the belt type actuator at low speeds may cause vibration and/or resonance. Therefore, please set the speed at 100mm/s or faster.(2) Since the RCP2 series use a pulse motor, the load capacity decreases at high speeds.Check in the Speed vs. Load Capacity graph to see if your desired speed and load capacity are supported.(3) The load capacity is based on operation at an acceleration of 0.5G. 0.5G is the upper limit for the acceleration.Actuator Specifications■ Lead and Load Capacity ModelRCP2-BA7-I-42P-54- 1 - 2 - 3 - 4 RCP2-BA7U-I-42P-54- 1 - 2 - 3 - 4(Note 1) Please note that the maximum load capacity decreases as the speed increases.■ Stroke and Maximum SpeedLegend 1 StrokeCable ListType StandardSpecial Lengths2 Compatible controllerCable Symbol3 Cable lengthP (1m)S (3m)M (5m)X06 (6m) ~ X11 (11m) ~ X16 (16m) ~ R01 (1m) ~ R04 (4m) ~ R06 (6m) ~ R11 (11m) ~ R16 (16m) ~Item Drive SystemPositioning RepeatabilityLost MotionAllowable Dynamic Moment (*) Overhang Load LengthAmbient Operating Temp./Humidity (*) Based on 5,000km travel life.Timing Belt ±0.1mm 0.1mm or lessRobot Cable* See page A-39 for cables for maintenance.Ma Mb Mc Ma McOption ListName Reversed-homeOption CodeNMSee Page → A-3353 RCP2-BA7/BA7UX10 (10m) X15 (15m) X20 (20m) R03 (3m) R05 (5m) R10 (10m) R15 (15m) R20 (20m)0~40°C, 85% RH or less (Non-condensing)Technical ReferencesA-50 250 500 750 1000 1250 1500 1750 (*Minimum Speed: 100mm/s) Speed (mm/s)Note:Graph 1 is for standard specifications, with settling time of 0.5s for calculating the positioning time.Graph 2 reflects some changes in the controller settings. The load capacity is lower, however the settling time is decreased to 0.2s.If the load capacity is lower than graph 2, and you want to shorten the positioning time, change the controller settings. (See the manual for details.)(Vertical operation is not possible.)Motor Mounting DirectionTop Bottom4 OptionsLead (mm)54 equivalentMax. Load Capacity (Note 1)Stroke (mm)600 ~ 1200 (50mm increments)Stroke Lead54 equivalentDescription600 ~ 1200 (50mm increments)1500(Unit: mm/s)Horizontal (kg) ~ 8Vertical (kg) Not AllowedActuator SpecificationsDirections of Allowable Load MomentsOverhang Load Length14 12Horizontal10 1 (settling time of 0.5s) 86 2 (setting time of 0.2s) 42 01LL


































































































   50   51   52   53   54